munotes®
Physics of Measurements and Sensors, solved papers

May 2026

Paper 1 of 1 19 questions answered 45 marks 1½ hours

munotes.in i
munotes.in ii
munotes.in iii

The Paper as Set

The questions in this volume are the questions asked at the May 2026 examination, reproduced as the University of Mumbai set them, in the order it set them. Nothing has been reworded, added or left out. Only the answers are ours. See the original question paper.

Duration 1½ hours  ·  Total marks 45  ·  19 questions answered

How to use this volume

Solve the paper first, under exam conditions and against the clock. Then read the answers here and mark your own. Reading a solution before attempting the question feels productive and teaches very little, because recognising an answer is not the same as being able to write one.

munotes.in iv

Q.1

Attempt any five · 15 Marks

munotes.in 1

(a)Write 3 points as the difference between Precision and Accuracy for measurements.[3]

Answer

For full marks, cover: a one-line meaning of each term, three clear points of difference in a table, and an example that shows the two can differ.

Meaning

Accuracy is how close a measured value is to the true value of the quantity.

Precision is how close repeated measurements of the same quantity are to one another.

Differences

PointAccuracyPrecision
1. What it comparesThe measured value with the true valueRepeated readings with one another
2. What it showsFreedom from systematic error, such as a wrong zero or a wrong scaleFreedom from random error, that is, small scatter
3. How it is expressedBy the error or percentage error from the true valueBy the spread of readings, such as the standard deviation
munotes.in 2
PointAccuracyPrecision
4. Need of a true valueA known true or standard value is neededNo true value is needed
5. Effect of repeatingA single reading can be judgedOnly a set of repeated readings can be judged

Example

A voltmeter reads 5.20 V, 5.21 V and 5.20 V for a true voltage of 5.00 V. The readings are precise, as they agree closely. They are not accurate, since all are about 0.2 V too high. This points to a systematic error such as a zero error.

If another meter reads 4.8 V, 5.2 V and 5.0 V, the average is accurate, but the readings are not precise.

A good instrument is both accurate and precise.

Conclusion. Accuracy is closeness to the true value, and precision is closeness of repeated readings to each other. A set of readings can be precise without being accurate.

munotes.in 3

The rest of the answers

You have read the paper as it was set and its first answer in full.

Every other answer, in every solved paper of this semester, opens with the solved papers.

Issue

Found an error in this volume? Report it and we will check it against the paper.

End of the papers That was the last solved paper for Physics of Measurements and Sensors. Next: Applied Mathematics II, May 2026 Next subject's papers